Comparison of the Intra and Postoperative Outcomes between 3-D Plates versus 2.0 mm Miniplates in Displaced Mandibular Angle Fractures

Atiya Nayab

Department of Oral and Maxillofacial Surgery, Liaquat University of Medical and Health Sciences, Jamshoro, Pakistan.

Kashif Ali Channar

Department of Oral and Maxillofacial Surgery, Liaquat University of Medical and Health Sciences, Jamshoro, Pakistan.

Tariq Hussain Sheikh *

Departmentof Oral and Maxillofacial Surgery, Institute of Dentistry, Liaquat University of Medical and Health Sciences, Jamshoro, Pakistan.

Aftab Ahmed Kumbhar

Department of Oral and Maxillofacial Surgery, Liaquat University of Medical and Health Sciences, Jamshoro, Pakistan.

Saqba Alam

Maxillofacial Consultant, Al Shifa Esthetic and Medical Centre, Pakistan.

Hajra Rana

Shaheed Mohtarma Benazir Bhutto Institute of Trauma, Pakistan.

Sip Narejo

Liaquat University of Medical and Health Sciences, Jamshoro, Pakistan.

*Author to whom correspondence should be addressed.


Abstract

Aim: This study aimed to compare intraoperative and postoperative outcomes by using Conventional 2mm Miniplate versus 3-D plates in management of Mandibular Angle Fractures.

Study Design: Randomized control trial.

Place and Duration of Study: Department of Oral & Maxillofacial Surgery (OMFS), Liaquat University Hospital, Hyderabad over 6 months.

Methodology: The study included a total of 60 patients having mandibular angle fractures randomly allocated into two groups. 30 of them were treated with 2mm conventional miniplates in  group A and 30 cases were 3D plated in group B. Outcomes such as intraoperative time was  measured in terms of minutes from the start of surgery till fixation using a stopwatch. Stability was assessed clinically and by postoperative radiographs. Mean and standard deviation was calculated for age duration of fracture and intraoperative time. Whereas frequency and percentage

 were calculated for gender, occupation, type of displacement. A comparison of the said parameters was also done, subsequently. The collected data were analyzed by SPSS version 22.0.

Results: The average age of the patients was 29.50±6.24 years. There were 38(63.3%) male and 22(36.7%) female. Mean intraoperative time in terms of minutes was significantly low in group B than in group A [45.27±7.09 vs. 50.50±7.12; p=0.006]. The rate of stability was 100% in group B and 90% in group A, however, it was not statistically significant between groups (p=0.237).

Conclusion: The results of the current study showed good stability, less procedure time required with a 3-D plating system. It could be concluded by the findings that the 3-D plating system has advantages over conventional 2mm miniplates.

Keywords: Facial skeleton, Miniplate versus 3-D plates, Mandibular angle fractures


How to Cite

Nayab, A., Channar, K. A., Sheikh, T. H., Kumbhar, A. A., Alam, S., Rana, H. and Narejo, S. (2022) “Comparison of the Intra and Postoperative Outcomes between 3-D Plates versus 2.0 mm Miniplates in Displaced Mandibular Angle Fractures”, Journal of Pharmaceutical Research International, 34(63), pp. 1–11. doi: 10.9734/jpri/2022/v34i637284.

Downloads

Download data is not yet available.

References

Xue AS, Koshy JC, Wolfswinkel EM, Weathers WM, Marsack KP, Hollier LH Jr. A prospective study of strut versus miniplate for fractures of mandibular angle. Craniomaxillofac Trauma Reconstr. 2013; 6(3):191–96.

Pal US, Singh RK, Dhasmana S, Das S, Das SK. Use of 3-d plate in displaced angle fracture of mandible. Craniomaxillofac Trauma Reconstr. 2013; 6(1):25–30.

Singh RK, Pal US, Agarwal A, Singh G. Single miniplatesosteo synthesis in angle fracture. Natl J Maxillofac Surg. 2011; 2(1):46-50.

Harjani B, Singh RK, Pal US, Singh G. Locking v/s non- locking reconstruction plates in mandibular reconstruction. Natl J Maxillofacial Surg. 2012;3:159-65.

Sadhwani S, Anchalia S. Conventional 2.0mm miniplates versus 3-D plates in mandibular fractures. Annals Maxillofac Surg. 2013;3(2):154-59

Yadav S, Agarwal A, Singh S, Anand KK. 3-D locking titanium miniplates in management of mandibular fracture: a prospective clinical study. J Dent Specialties. 2015;3(1):64-67.

Yadav D, Mishra R, Shashank T. 3 - dimensional versus conventional titanium miniplateosteo synthesis in mandibular fracture– a comparative study. AdvRes Dent and Oral Hyg. 2019;1(1):11

Sudheer R, Chakravarthy BD, Vura N. management of angle mandible fractures by 3D rectangular grid plate: a prospective study. J Maxillofac. Oral Surg; 2019.

Sukegawa S, Kanno T, Masui M, Sukegawa-Takahashi Y, Kishimoto T, Sato A, Furuki Y. Which fixation methods are better between three-dimensional anatomical plate and two miniplates for the mandibular subcondylar fracture open treatment?. J Cranio- Maxillofac Surg. 2019;47(5):771-7.

Wusiman P, Yarbag A, Wurouzi G, Mijiti A, Moming A. Three dimensional versus standard miniplate fixation in management of mandibular fractures: a systematic review and meta-analysis. Journal of Cranio-Maxillofac Surg. 2016;44(10):1646-54.

Jain MK, Kerur P. Bite Force as a parameter for comparison between three-dimensional and standard titanium miniplates for the management of anterior mandibular fractures: aprospective randomized double-blinded clinical trial. J Maxillofac Oral Surg. 2019;18(2):249-55.

Hajrani B, Singh RK, Pal US, Sing G. Locking v/s non locking reconstruction plates in mandibular reconstruction. Natl J Maxillofac Surg. 2012;3:1 59-65.

Balkirshnan R, Ebenzer V, Dakir A. Three dimensional titanium mini plates in managementof mandibular fractures. Biomed and Pharmacol J. 2014;7:241-46.

Yadav S, Agarwal A, Singh S, Kumar S, Anand KR, ChhabraV. 3-D locking titanium miniplates in management of mandibular fracture:A prospective clinical study.J Dent Specialit. 2015;3:64.

Sadhwani BS, Anchlia S. Conventional 2.0 mm miniplates versus 3-D plates in mandibular fractures. Ann Maxillofac Surg. 2016;3:154-59.

Malhotra K, Sharma A, Giraddi G, Shahi AK. Versatility of titanium 3Dplate in comparison with conventional titanium miniplate fixation for the management of mandibular fracture. J Maxillofac Oral Surg. 2012;11:284-90.

Siddiqui FI, Naphade MV, Naphade UM, Adwani DG, Shroof PR, Anwar SS. Management of anterior mandibular fractures using two different fixation methods. J Craniofacial Sci. 2016;4:4-9.

Zafar KJ, Khurram M, Janjua OS, Saleh MI, Khalid S, Khali MU, Ahmed R. Comparison of three-dimensional plates versus conventional two miniplates for open reduction and internal fixation of mandibular symphysis and parasymphysis fractures. APMC. 2019; 13(1):51-5.

Gokkulakrishnan S, Singh S, Sharma A, Shahi AK. An analysis of postoperative complications and efficacy of 3-D miniplates in fixation of mandibular fractures. Dent Res J. 2012;9(4):414-21.

Al-Tairi NH, Shoushan MM, Khedr MS, Abd-alal SE. Comparison of three-dimensional plate versus double miniplate osteosynthesis for treatment of unfavorable mandibular angle fractures. Tanta Dental Journal. 2015;12(2):89-98.

Kumari M, Channar KA, Punjabi SK, Memon M, Shams S, Hassan SG. Comparison between Conventional 2.0 mm Miniplates versus 3-D Plates In Management of Mandibular Fractures. Journal of Pharmaceutical Research International. 2020 Dec 30:83-8.

EL Nakeeb, EL Dibany, Shokry MM. A comparative study between 3-d plates and conventional miniplates for internal fixation of anterior mandibular fractures. Alexandria Dental Journal. 2016;41:253-260

Kumar BP, Kumar J, Mohan AP, Venkatesh V, Kumar R. A comparative study of three-dimensional stainless-steel plate versus stainless steel miniplate in the management of mandibular parasymphysis fracture. J Bio Innov. 2012;1(2):19-32.

Kinra PK, Jayakumar K, Soumithran CS, Michael MJ, Passi D, Singh M. Comparative evaluation of bite force analytical study following mandibular osteo-systhesis using three-dimensional and conventional locking miniplates. Natl J Maxillofac Surg. 2017;8(1):34-40.

Jain MK, Manjunath KS, Bhagwan BK, Shah DK. Comparison of 3-dimensional and standard miniplate fixation in the management of mandibular fractures. J Oral Maxillofac Surg. 2010;68:1568–1572.

Vineeth K, Lalitha RM, Prasad K, Ranganath K, Shwetha V, Singh J. A comparative evaluation between single noncompression titanium miniplate and three dimensional titanium miniplate in treatment of mandibular angle fracture-a randomized prospective study. J Craniomaxillofac Surg. 2013;41:103– 109.

Malhotra K, Sharma A, Giraddi G, Shahi AK. Versatility of titanium 3D plate in comparison with conventional titanium miniplate fixation for the management of mandibular fracture. J Maxillofac Oral Surg. 2012;11:284–290.