Functional Outcome of Shaft of Humerus Fractures Managed Surgically by Dynamic Compression Plating Technique

Midhun Krishnan *

Sree Balaji Medical College & Hospital Affiliated to Bharath Institute of Higher Education and Research, Chennai, Tamil Nadu, India.

*Author to whom correspondence should be addressed.


Abstract

The study analyzed 20 cases of fracture shaft of hummers treated with Dynamic Compression Plate. There was a male preponderance in our study 17 (85%). Almost Also 13% of patients treated by functional bracing end up with cosmetically unacceptable angulation of>15%, whereas all operative procedures achieve good alignment of the fractured bone was observed. The rate of union in Plate osteosynthesis is 93% and the time of union is 16 - 20 weeks, and more than 90% united in 18 weeks and 7% went for non union.

Keywords: Osteosynthesis, dynamic compression plate


How to Cite

Krishnan, M. (2021) “Functional Outcome of Shaft of Humerus Fractures Managed Surgically by Dynamic Compression Plating Technique”, Journal of Pharmaceutical Research International, 33(49B), pp. 101–104. doi: 10.9734/jpri/2021/v33i49B33345.